Download Print this page

Specifications; Installation - Optex OA-FLEX AIR T User Manual

Advertisement

MANUFACTURER'S STATEMENT
MANUFACTURER'S STATEMENT
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or
death of a person.The meanings of the symbols are as follows.
Disregard of warning may cause the improper operation causing death or serious injury of
WARNING
a person.
Disregard of caution may cause the improper operation causing injury of a person or damage to
CAUTION
objects.
Special attention is required to the section of this symbol.
NOTE
NOTE
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the
installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock.
NOTE
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door.
-Wet floor.
-Vibrating header or mounting surface.
-Moving objects or objects that emit light near the detection area.
-Highly reflecting floor or highly reflecting objects around the door.
WORKING PRINCIPLE
This sensor is designed to detect a hand approaching to a touchless plate as a knowing act activation device.
Please make sure to understand the following working principle.
This sensor sends primary activation output when both "FLEX EYE and 2nd to 4th row" detect some object.
After the detection until the door fully closes, 2nd to 6th rows work as a Secondary Activation output.
"FLEX EYE" means a detection area for the hand.
Secondary Activation area is from the 2nd row to the 6th row.
FLEX EYE
6
5
4
3
2
1
6
5
4

SPECIFICATIONS

Model
: AIR-SLIDE 2
Cover color
: Black
Mounting height
: 6'7"(2.0m) to 9'10"(3.0m)
Detection area
: See DETECTION AREA
Detection method
: Active infrared reflection(*1)
FLEX EYE
: Depth : -14° to +2°
angle adjustment
Width : ±42° ( 7 clicks with 6°every
one click-Reft/Light )
Secondary
: Depth : -16° to +0°
Activation area
Width : ±7° ( 2 clicks with 3.5°every
angle adjustment
one click-Reft/Light )
Power supply
: 12 to 24V AC ±10% (50/60Hz)
12 to 30V DC ±10%
Power consumption
: < 2.0W (< 3VA at AC)
Operation indicator
: See Operation indicator table
Primary, Secondary
: Form A relay
Activation output
50V 0.3A Max. (Resistance load)
Operation indicator table
Status
Operation indicator color
Set-up
Yellow Blinking
Stand-by (Installation mode)
Stand-by (Operation mode)
BLUEZONE (1st row) detection (*2)
2nd row detection
Red Blinking
3rd row detection
4th-6th row detection
Orange
FLEX EYE detection (*3)
Fast Purple Blinking
FLEX EYE & 2nd-4th row detection
Signal saturation(Secondary Activation area)
Slow Green Blinking
Signal saturation (FLEX EYE)
Slow Purple Blinking
Sensor failure
Fast Green Blinking
The specifications herein are subject to change without prior notice due to improvements.
NOTE
*1 : BLUEZONE (1st row), 2nd and 3rd rows have a presence detection function.
*2 : See BLUEZONE
*3 : See FLEX EYE MODE
OUTER DIMENSIONS AND PART NAMES
9 10/16" (245)
4 15/16" (125)
1 7/16" (36)
1 11/16" (43)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
AIR-SLIDE 2
FLEX EYE
3
2
1
Output hold time
: Approx. 0.5 sec.
Response time
: < 0.3 sec.
Operating temperature
: -4 to 131°F (-20 to +55°C)
Operating humidity
: <80%
IP rate
: IP44
Weight
: 8.8oz (250g)
Accessories
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Power & Primary Activation
output cable 8'2" (2.5m)
1 Secondary Activation output
cable 8'2" (2.5m)
1sec.
Yellow
Green
Blue
Red
Purple
[inch (mm)]
Touchless plate
1 7/16" (37)
4" (102)
(1) Power & Primary Activation output Connector
(2) Secondary Activation output Connector
(3) Mounting holes
(11)
(4) Operation indicator
(5) FLEX EYE Width angle adjustment screw
(6) FLEX EYE Depth angle adjustment screw
(7) Dipswitches
(8) Secondary Activation area angle adjustment screw
(9) Secondary Activation area width adjustment screws
(9)
(10)
(10) Detection window
(11) Area adjustment tool
BLUEZONE
When dipswitch 11 is set to ON, the BLUEZONE area, that provides extra safety over the threshold, is activated.
In case the BLUEZONE function is not required, set dipswitch 11 to OFF.
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 11.
FLEX EYE MODE
Dipswitch 15 can adjust the FLEX EYE function ON or OFF.
- FLEX EYE mode ON.(Dipswitch 15 OFF)
During FLEX EYE and Secondary Activation area are both working,
Primary Activation output is emited.
When only one function is working, Primary Activation output is not emited.
- FLEX EYE mode OFF.(Dipswitch 15 ON)
You can use AIR-SLIDE 2 as normal Autodoor activation sensor.
You do not need to adjust FLEX EYE function.
DETECTION AREA
BLUEZONE
(1st row)
2nd row
3rd row
4th row
5th row
6th row
I
The actual Secondary Activation area may become smaller depending on the ambient light, the color /
NOTE
material of the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50mm / sec. or faster than 1500mm / sec.

INSTALLATION

1
1. Affix the mounting template at the desired mounting position.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
FLEX EYE
2. Drill two mounting holes of ø1/8" (ø3.4mm).
3. To pass the cable through the header, drill a wiring hole of ø3/8" (ø10mm).
BLUEZONE
4. Remove the mounting template.
(1st row)
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
2nd row
3rd row
Header
4th row
Sensor
5th row
6th row
Y
X
Door
Floor
CAUTION
Risk of getting caught.
Wire the Power & Primary Activation output cable and Secondary Activation output cable to the door controller
2
properly as shown in the drawing below. The Secondary Activation output requires an input at the door control that
is inhibited(ignored) when the door controller has a safety beam input.If not then install a position / inhibit switch in
1sec.
series with the blue wire output(see drawing below).
Door controller
safety beam input
Door controller
Activate input
Power supply
Grey
Yellow
AIR-SLIDE 2
Power
Primary
Activation
output
Inhibit switch
when door
Inhibit switch status
is closed
3
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See ADJUSTMENTS 4. Dipswitch settings)
Make sure to connect the cable correctly to the door controller before turning the power ON.
NOTE
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
4
Place the housing cover.
If wiring is to be exposed, break the knockout.
WARNING
Danger of electric shock.
2nd row
BLUEZONE
2nd row
(1st row)
3rd row
3rd row
FLEX EYE
A
A
B
C
B
D
C
E
D
E
F
F
G
G
H
J
H
: Emitting spots
J
: Emitting spots
(can be eliminated)
H : Height from the floor to the bottom of the header
(The mounting height is "H + Y".)
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
Maximum mounting distance (Y)
H
X
7'7" (2.30)
6'7" (2.00)
0
8" (0.20)
2" (0.05)
8" (0.20)
H
4" (0.10)
8" (0.20)
8" (0.20)
6" (0.15)
6" (0.15)
5" (0.13)
5" (0.12)
8" (0.20)
-
-
-
10" (0.25)
12" (0.30)
-
-
NOTE
Make sure not to mount the sensor lower than the bottom of header.
Make sure to affix the mounting template as described in the above chart ,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the header.
without
Power &
Secondary
Primary Activation
Activation
output cable
output cable
Blue
Secondary
Activation
output
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain-cover
(Separately available) otherwise electric shock or breakdown of
the sensor may occur.
BLUEZONE
(1st row)
Secondary
Activation area
FLEX EYE
[ feet,inch (m) ]
6'7" (2.00)
7'7" (2.30)
8'2" (2.50) 9'10"(3.00)
8" (0.20)
9" (0.23)
10" (0.26)
1'(0.31)
1'8" (0.45)
1'8" (0.52) 1'10" (0.56)
2'3"(0.68)
2'7" (0.80)
3' (0.92)
3'4" (1.01) 3'12"(1.21)
3'7" (1.09)
4'1" (1.25)
4'6" (1.36)
5'4"(1.63)
5' (1.53)
5'9" (1.76)
6'4" (1.92)
7'7"(2.30)
6'7" (2.00)
7'7" (2.30)
8'2" (2.50) 9'11"(3.01)
3'5" (1.04) 3'11" (1.20)
4'8" (1.43)
5'1"(1.56)
I
5'8" (1.72)
6'6" (1.98) 7'11" (2.15)
8'6"(2.59)
7'5" (2.26)
8'6" (2.60)
9'3" (2.82) 11'1"(3.39)
Charts show the values in the following
Secondary Activation area angle
adjustment settings ;
Depth :0°
Width :0°
[feet,inch (m)]
8'2" (2.50)
9'2" (2.80)
9'10" (3.00)
No limit
8" (0.20)
8" (0.20)
0
8" (0.20)
8" (0.20)
0
7" (0.19)
8" (0.20)
0
6" (0.14)
6" (0.15)
0
4" (0.11)
5" (0.12)
0
-
-
-
Door controller
with
safety beam input
Grey
AIR-SLIDE 2
Power
Secondary
Primary
Activation
Activation
output
output
Knockout
Knockout

Advertisement

loading