Specifications - Optex SIP-3020/5 Installation Instructions Manual

Synthesized intelligent pir redwall-v series
Table of Contents

Advertisement

2

SPECIFICATIONS

Applicable
SIP-3020/5
models
Model
Detection method
Coverage
(Main area)
Coverage
(Creep zone)
Number
Main area
of
detection
Creep
zones
zone
Mounting height
Power input
With optional
heating unit
Current draw
With optional
heating unit
Far alarm
and
Operation
Near alarm
indicator
Creep zone
alarm
Alarm period
Warm-up period
Detection range
selector
Alarm interval period
Detection logic
selector
Tamper output
* UL-7
Trouble output
* UL-7
Main area
Alarm
output
Creep
* UL-7
zone
Sensitivity selector
Without
optional
heating
Operating
unit
temperature
With
optional
heating
unit
IP rating
Dimensions
(H × W × D)
Weight
Accessories
* UL-6: Not evaluated by UL.
* UL-7: All relay outputs are resistive load only.
SIP-4010/5
SIP-404/5
SIP-3020/5
SIP-400/5
Passive infrared
30 x 20m
40 x 0m
(00 x 65ft.)
(30 x 33ft.)
(30 x 3ft.)
* Environmental condition may effect to the size of
coverage area.
* It may be reduced to 90% in the worst case.
3×5 m (0×6 ft.) at 2.3 m (7.6ft.) height
6×9 m (20×30 ft.) at 4 m (3ft.) height
Detection angle adjustable
74 zones
48 zones
36 zones
2.3 to 4m (7.6 to 3ft.)
 - 6V DC
22 - 26V AC
* UL-6
22 - 26V AC
* UL-6
45mA max. (2V DC)
85mA max. (24V AC)
* UL-6
425mA max. (24V AC)
Red LED
Red LED
Approx. 2 sec.
Approx. 60 sec.
Far area: ON / OFF
0 / 5 / 30 / 60 sec.
AND/OR
N.C. 28V DC, 0.1A max.
N.C. 28V DC, 0.2A max.
N.C.28V DC, 0.2A max.
N.O.28V DC, 0.2A max.
N.C.28V DC, 0.2A max.
N.O.28V DC, 0.2A max.
Far: SH/H/M/L Near: SH/H/M/L
Creep zone: SH/H/M/L
-25 to +60°C (-3 to +40°F)
-40 to +60°C (-40 to +40°F)
Main unit :IP65
Chassis :IP55
248 x 102 x 266 mm
(9.8 x 4.0 x 10.5 in.)
1.4 kg (48 oz.)
2 Screws
2 Nylon anchors
 Paper template
 Allen key
 Area masking seal
 Tweezers
 Instruction manual
 Area plate
 Fixing rubber form
DIMENSION
SIP-404/5
SIP-3020/5, 4010/5, 404/5
40 x 4m
24 zones
* UL-6
OPTION
OPM-WT, AWT-3
AVF-
SIP-MINIHOOD
SIP-HU
* UL-8: All option equipment are not evaluated by UL.
Cautions>>
When SIP-HU is used, the power for SIP unit should be
22 - 26V AC.
These units are designed to detect movement to activate CCTV
system. Being only part of a complete surveillance system,
we cannot accept responsibility for any damage or other
consequences resulting form the activation of the unit.
This product confirms to the EMC Directive 2004/108/EC.
Specifications and design are subject to change without prior
notice.
* UL-6
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com/
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec/
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optexeurope.com/
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
URL: http://www.optex.nl/
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com/
- 2 -
02
266
(4.0)
(0.5)
90
(3.6)
2
(0.83)
-Audio Walk Tester
-Area View Finder
-Sun/Snow shield
-Heating unit
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net/
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl/
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net./in/en/sec/
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com/
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com/
96
(3.78)
2
(0.83)
Unit:mm (inch)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sip-4010/5Sip-404/5

Table of Contents