5.4.3 Rope testing
Ropes must be inspected at least once a year by a qualified person. Depending on use,
a weekly inspection is recommended.
With regard to safety, ropes must be discarded in good time. This must be done if the
following damage is detected:
Breakage of a stranded wire (Fig. 1)
Bruising (Fig. 2)
Loop formation
Kinks and prongs (clasps) (Fig. 3)
Basket formation (Fig. 4)
Wire breaks in large numbers (Fig. 5)
Fig. 1 and 2
Fig. 3 and 4
Fig. 5