Signal Mode .
Configures framing detector on
P2E2DS3 module.
Service Profile. Provisioning Rules:
1. DS3 Port Service Profile provisioning must be the same at
both ends of the link.
2. DS3 ports 1 and 2 can be provisioned independently.
3. Provisioning a DS3 port TDM2TDM prevents cross-
connecting that DS3 port to Ethernet access ports 1-4.
4. Flow ID number is unique for that DS3 port and once
assigned, cannot be repeated throughout the network.
Figure 4 - 18 P2E3DS3 Module Provisioning TDM2ETH (Sheet 2 of 2)
4-42
Select:
Disabled – No alarm and no AIS insert
Unframed – Insert AIS on LOS (Tx & Rx)
Framed – Insert AIS on LOF and LOS (Tx & Rx)
Apply settings
for this port
number.
TDM2Eth
NOTE: DS3 requires TDM2Eth Service Profile.
In TDM2Eth mode, allj of the DS3's are collected, packetized and
made available over Ethernet at the last node.
Payload Size
Number of data bits
without overhed in Mb.
The purpose of TDM Clock Source
provisioning is to select the mode that
will be used to sync TDM DS3 data to
the node Synchronization source.
Select ADAPTIVE to sync TDM output
to packets. Select DIFFERENTIAL to
sync TDM output to NE Synchronization
source. Select TDM_Line_In to sync
TDM output to TDM input.
ECID (Emulation IDentification) is a network
unique 8-bit code identfier used along with V-Lan
to identify and switch individual DS3 lines through
the CSM.
• Unique network number
• Same ECID for same line at opposite end
• Entered only at terminating ends of line
(Tx/start and Rx/end, both directions)
• Not required for thru-repeaters
• Required for dropped and inserted lines at
drop and insert repeater
• Main and Spare the same in 1+1 configuration
Apply settings
• ECID and Flow ID for line can be the same
to all port
number
numbers.
9500-4014A