3.5

DS3 CONNECTIONS

DS3 cable requirements depend on MSS shelf/module application.
3.5.1
Unprotected Configuration Cabling
See
Figure
3-7. Recommended connectorized cable assembly PN 3EM22687AA/AB (male
mini BNC-to-male mini BNC, 2/5 meter lengths).
3.5.2
Protected Configuration Cabling
See
Figure
3-7. Recommended splitter assembly – PN 3EM22900AA (splitter in/combiner
out-bulkhead female mini BNC; splitter out combiner in – two male mini BNC, 2/5 meter
lengths). The mini BNC bulkhead connector can be permanently installed on the rack-
mounted DS3 interface panel – PN TBD.
Mini BNC Connectors
Line 1
Out
DS3 Line 1
Output
Intput
9500 DS3 Trib (Protected Pair)
MSS-8 Shelf
Main Side
BNC Panel Mount
Customer Connectors
Line 1
In
DS3 Line 2
DS3 Line 3
Output
Intput
Output
Intput
Figure 3-7 DS3 Connections
Spare Side
Mini BNC Connectors
Line 2
Out
DS3 Line 4
DS3 Line 5
Output
Intput
Output
Intput
Line 2
In
DS3 Line 6
Output
Intput