4.7.3.4
MD300 (Slot#7-8 MD300: 1+1 HSB) Equipment Protection
Hot Standby (HSB) Transmission Protection Switching (TPS) - shown as HSB Protection
on CT screen. See
Figure 4 -
1
2
3
Figure 4 - 24 MD300 HSB Protection Provisioning (Sheet 1 of 2)
4-58
24.
Click
to apply.
5
4
Choose Revertive if you want
traffic on the protection channel to
automatically switch back to the
main channel when alarms clear
or a switch command is released.
Choose Not Revertive if you want
traffic on the protection channel to
stay on the protection channel
when alarms clear or a switch
command is released.
Traffic can be manually switched
back to the main channel.
Choose None (Default) if there is no command required
or to release a manual or forced switch.
Choose Manual if you want to switch from Main to
Standby DS1 Access or Standby to Main DS1 Access
and still allow the channel to switch automatically if
there is a failure.
Choose Lockout if you want to prevent switching traffic
on main channel to standby (protection) channel.