If Connections; To Type N Adapter Bracket Connections; Type N Adapter Bracket To Odu Cable Connections - Alcatel-Lucent 9500 MPR User Manual

Microwave packet radio
Hide thumbs Also See for 9500 MPR:
Table of Contents

Advertisement

Do not apply battery power until it is determined that A and
B battery cables with isolated returns and power cables are
wired correctly. With power applied, reverse polarity on wir-
ing (+batt wired to -batt pin on connector) can cause power
supply fuse to blow.
Grounding of pole, antenna, customer interfaces, and all entrances to
the building interior shall meet local electrical code and standard
business practices.
3.3

IF CONNECTIONS

IF connections between the MSS and ODU require connectors, cables, brackets, lightning
arrestors, cable hangers, and grounding kits. The following paragraphs describe cables and
connectors and associated brackets. Refer to Installation section on CD for descriptions
and details for the recommended lightning arrestors and grounding kits.
3.3.1
MOD-300 to Type N Adapter Bracket Connections
The IF input/output of the MOD-300 module is connected to the type N adapter bracket
(PN 3DB18197AA) via a coax cable jumper. Recommended jumper cable PN 3DB18205AA
(shielded coax cable, 12 in, with QMA slip-fit connector on one end type N bulkhead style
connector on other end). See
3.3.2

Type N Adapter Bracket to ODU Cable Connections

IF input/output to/from ODU is connected to type N connector on jumper cable at type N
adapter bracket. Recommended LMR 400 coax cable PN 1AC14320002 (low-loss RG-8
shielded coax cable that uses type N connector both ends). Typically, cable is cut to length
and connectors installed on site. Maximum cable length is 1000 ft.