Alcatel-Lucent 9500 MPR User Manual page 124

Microwave packet radio
Hide thumbs Also See for 9500 MPR:
Table of Contents

Advertisement

Prerequisites:
• The Ethernet port (source) and MD300 module (destination) must be
enabled on the respective CSM and MD300 module provisioning screens.
• The Service Profile on the P32E1DS1/P2E3DS3 module Settings screen
must be set to TDM2ETH for each DS1/DS3 cross connected.
Procedure:
1.
Drag mouse and draw line between ETH port and PDH. PDH-ETH pop-up
displays.
2.
Select Flow ID of DS1/DS3 line to be cross connected from Flow ID drop-down
list on the pop-up.
3.
The destination MAC Address of the MEF-8 Interworking Function (IWF)
device where the DS1 /DS3 flow will be terminated must be entered in the
MAC Address field on the pop-up.
When cross connecting multiple lines, the original line drawn between
the two ports remains in place. The new line is drawn over the top of
the original line.
4.
Repeat steps 1, 2, and 3 as many times as necessary to cross connect up to
32 DS1 lines and/or twice to cross connect 2 DS3 lines.
5.
On the PDH-ETH pop-up, click
6.
On the Cross Connections screen, click
4-72
Note
OK
.
Apply
.