Equipment
Alarm Description
Firmware Download
In Progress
Degraded Signal
License Mismatch for
Equipment Provisioned
ODU
Card Fail
Equipment Mismatch
RX Function Fail
RF Frequency Mis-
match
Shifter Frequency Mis-
match
TX Power Mismatch
Software Mismatch
ODU Not Responding
Firmware Download
In Progress
EPS - Equipment Protection Switching
LOS - Loss of Signal
RPS - Radio Protection Switching
TCA - Threshold Crossing Alarm
UAT - Un-Available Time
5-8
Table 5-1 Alarm Matrix (Cont.)
1+1
1+0
1+FD
HS
Minor
Minor
Minor
Minor
Minor
Minor
Major
Major
Major
Major
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Major
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Most Probable
Action
Cause
Download status
Wait for downloading
to complete
Low quality sync sig-
Replace MD300 mod-
nal from MD300
ule
module
MD300 module type
Replace MD300 mod-
does not match mod-
ule with correct mod-
ule type stored in
ule type
memory on the Core
module flash card
ODU failed
Replace ODU
ODU does not
Replace ODU
match ODU config-
ured in Core mem-
ory
ODU receiver cir-
Replace ODU
cuit failed
Frequency out-of-
Re-configure frequency
range of configured
TX frequency
Configured shifter
Re-configure shifter
value not supported
value
by ODU
Configured TX
Re-configure TX power
power value not sup-
value
ported by ODU
Software version on
Download correct soft-
ODU does not
ware version
match software ver-
sion on Core
Loss of communica-
1. Replace ODU._2.
tion with ODU.
Replace alarmed
MD300 module.
Download status
Wait for downloading
to complete