14

Changing group of parameters

a Disconnect the electrical power contact.
b Press the LEARN BUTTON (LRN) and keep it depressed.
c Connect the electrical power contact.
d Watch the ERROR LED.
3 s
e Release the LEARN BUTTON after the 5 seconds (LED is out).
The ERROR LED flashes a number of short flashes that corresponds to the parameter group
number (see table). After a short pause the LED will repeat the group number, and so on.
f Pushing the LEARN BUTTON once, increases the parameter group number. When the
highest parameter group number is reached it will start with number 1 (default) again.
g Push the button until you get the requested parameter group.
h Disconnect the electrical power contact.
i Next time the electrical power is connected, the operator will use the new group of parameters.
1007718-US-3.0
1 s
5 s
Issue 2012-06-27
14 Changing group of parameters