12 Start-up
12.2.9
Configuration parameters
Parameter name
Hold open time
Opening time
Closing time
Arm system
Push and go
Power assist
Extend closing torque
Stop on stall
Select lock voltage
Select lock power
Push and close
Key impulse hold open time
Number of lock retries
Lock kick
Reverse upon obstruction
Lock release time
Open / Close on inner impulse
44
Default settings
Value
2.5s
2s - 6h
4.5s
4.5s - 9s
4.5s
4.5s - 9s
Push
Push / Pull
Not active
Not active / Active
Off
Off / Low / Medium / High
0 (Lowest)
0 (Lowest) - 10 (Highest)
Active
Not active / Active
24V
12V / 24V
Lock with power
Lock with power / Lock without power
Not active
Not active / Active
2s
2s - 25s
1 time
0 - 2 times
Not active
Not active / Active
Active
Not active / Active
0.5s
0s - 5s
Not active
Not active / Active
Issue 2020-10-27