6000 Series Wiring Diagrams
Electric Latch Retraction Exit Device Powered Through 782N Controller
(change factory pre-wiring to illustration below - move GND to COM)
Door is normally closed and latched.
Activating switch will retract exit device
latch bolt and door will automatically
open. Door will close after hold open
time delay has elapsed.
Exit device allows egress at all times,
including during power failures.
Activation can be wall switch, card
reader, key switch, etc (Normally open
momentary dry contacts).
Contact Tech Support for other devices
or manufacturer's instructions.
To turn on relay (Relay 2), Latch
Retraction (Output Connections, page
14) and/or Open Delay (Set options,
page 8) features must be turned on
using adjustment procedures on pages
indicated.