Setup Menu: 2. Communications - Stanley Theta Controller User Manual

Table of Contents

Advertisement

2.8.2 Setup Menu: 2. Communications

Communication Screens
This area displays the setting of the serial Communications ports on the bottom of the Theta.
To change the operation of the serial ports the Theta firmware must be changed.
eTB – Allows the controller to communicate to the Controller Gateway software on a
computer. See Appendix A. Toyota – an error proofing protocol used in handheld tool
applications in Toyota facilities.
OPEN – An error proofing / data collection protocol used in tool applications at Ford, Honda
and other facilities. This protocol can be used by others as it does not take special equipment
like the Toyota protocol.
The Theta controller supports the following MID's (Rev 1 only) on the OPEN protocol.
MID
Description
1
MID_COMMUNICATIONS_START
3
MID_COMMUNICATIONS_STOP
10
PS_NUMBERS_UPLOAD_REQUEST
14
PS_SELECTED_SUBSCRIBE
17
PS_SELECTED_UNSUBSCRIBE
18
SELECT_PS
19
SET_PS_BATCH_SIZE
20
RESET_PS_BATCH_SIZE
30
JOB_NUMBERS_UPLOAD_REQUEST
34
JOB_SELECTED_SUBSCRIBE
37
JOB_SELECTED_UNSUBSCRIBE
38
SELECT_JOB
39
RESTART_JOB
40
TOOL_DATA_UPLOAD_REQUEST
42
DISABLE_TOOL
43
ENABLE_TOOL
60
LAST_TIGHTENING_RESULTS_DATA_SUBSCRIBE
63
LAST_TIGHTENING_RESULTS_DATA_UNSUBSCRIBE
70
ALARM_SUBSCRIBE
73
ALARM_UNSUBSCRIBE
80
READ_TIME_UPLOAD_REQUEST
24
Options Screen
Select Communications by pressing the
SETUP interactive menu button on the Run
screen.
Press 2 or highlight selection and press
Toggle button.
The Theta controller has two serial
communication ports. COM 1 must be used
for eTB. COM 2 can be used for error
proofing or data collection network protocols,
barcode reading and printing of fastening
cycle data.
User Manual

Advertisement

Table of Contents
loading

Table of Contents