Stanley Theta Controller User Manual page 20

Table of Contents

Advertisement

User Manual
Wizard Screens
Options Screen
Angle Target – The number of degrees of
rotation the socket turns during this step.
Snug Torque – Angle measurement, for the
target angle, starts at this torque.
Speed – The speed of the tool during this step.
Max Torque – The maximum allowed torque
during this step.
Pre-Torque is a Torque Control /Angle
Monitoring strategy in the same direction for
which the final tool strategy is programmed.
The tool runs the fastener to a preliminary
torque level and suspends the fastening cycle
for a period of time. After a time delay, the
Audit step begins. If selected, this is the first
step AFTER Start Delay. Options include:
Torque Target – The Target Torque for this
step.
Delay Between Steps – The time period to
suspend the tool strategy before continuing.
If SYNCHRONIZE is used, the tool waits
here until all synchronized tools have
completed this step before continuing.
ATC (Adaptive Tightening Control) is not a
strategy or a step. It is an algorithm that
modifies the tool's speed as the torque rises.
Select this, instead of a downshift, as an
option to increase tool capability.
There are no options with this selection. The
values are calculated automatically.
Backout Fastener – Accomodates assembly
procedures requiring partial removal of the
fastener before additional components can be
added to the joint. Creates a Backoff strategy
step after the Audit step. The tool stops after
achieving either the angle or torque target. If
selected, this is the first step after the Audit
step. Options include:
Angle Target – The number of degrees of
rotation the socket turns during this step.
Torque Target – The Target Torque for this
step.
Speed – The socket speed during this step.