Setup: Job Tab - Stanley Theta Controller User Manual

Table of Contents

Advertisement

Theta Controller
Wizard Screens

2.8.1.2 Setup: Job Tab

Jobs, Tasks and Steps are required to setup a tool strategy. Inputs and Triggers are used to select
specific Jobs or Tasks with different tool strategies, including Error Proofing (bolt counting).
Program Job parameters according to the plant integration strategy desired and then program
Task(s) and Step(s) to create the tool strategy.
Job Tab Screens
Tool settings apply to all Steps.
Barcode Id – This is a mask that when equal to an incoming PART ID selects this Job as the
active Job. The PART ID can come from the serial port, the OPEN protocol, the Toyota PI
protocol or the keypad itself. Use periods (.) to mask the negligible portions of the PART ID;
use the exact characters in their exact PART ID positions to select the Job.
Example: If a PART ID is 123ABC and if the 3A determines when this Job is to run
(the third and fourth positions), then enter . . 3 A . . as the parameter value. Notice
that the periods (.) match the length of the expected PART ID.
Auto Sequence Tasks – When set to Yes, the controller automatically sequences from Task 1 to
the final Task in the Job (after the fastener count in each Task is complete). No requires an
Programming
Options Screen
Press the FINISH interactive menu button to
close the Wizard.
The Job Tab screen appears. This allows
parameter changes to be made prior to saving
Wizard programming. To save, press the
EXIT interactive menu button.
Press the YES interactive menu button to save
changes. This saves the parameters and opens
the Run screen.
Options Screens
Select Jobs by pressing the SETUP button on
the run screen.
Press 1 Jobs or highlight selection and press
Toggle button.
or
Name – Name the Job to define the operation
performed (15 character maximum). Use the
up/down arrows to spell with letters or use the
numeric keypad.