Indicates an electrical hazard.
This icon appears as a part of a
Danger, Warning, or Caution
notice.
To Avoid Injury:
•
Read and understand all the safety recommendations and all operating instructions before
operating tools and controllers. Save these instructions for future reference.
•
Train all operators in the safe and proper use of power tools. Operators should report any
unsafe condition to their supervisor.
•
Follow all safety recommendations in the manual that apply to the tools being used and the
nature of the work being performed.
•
Verify that all warning labels illustrated in this manual are readable. Replacement labels are
available at no additional cost from STANLEY ASSEMBLY TECHNOLOGIES.
Qualified Personnel
To Avoid Injury:
•
Only allow suitably qualified personnel to install, program, or maintain this equipment and or
system.
•
These persons must be knowledgeable of any potential sources of danger and maintenance
measures as set out in the Installation, Operations, and Maintenance manual.
•
This product must be transported, stored, and installed as intended, and maintained and
operated with care to ensure that the product functions correctly and safely.
•
Persons responsible for system planning and design must be familiar with the safety concepts
of automation equipment.
1.3 Specifications, Layout and Display
Dimensions
Width:
Height:
Depth:
Weight:
Operating Conditions:
Temperature:
Humidity:
100 – 126 VAC, 50/60 Hz, 15 – 20A service or
Power Source:
207 – 253 VAC, 50/60 Hz, 10 – 16A service
Power Consumption:
Stand by:
Continuous:
Tool Motor Power:
Service Rating:
Consumption
@ 115 VAC:
@ 230 VAC:
Continuous kVA:
* 200- 240 VAC recommended, heavy duty power cord required with 100- 120 VAC
2
Indicates an item of special
interest.
W A R N I N G
W A R N I N G
6.0 in
152 mm
14.2 in
361 mm
8.2 in
208 mm
15 lb
7.0kg
32 to 122 ºF (0 to +50 ºC)
0 to 95 % non-condensing
0.2 A (amperes)
1-2.5 kVA
EC02/EC22
EC33/EC34
15A
15A
10A
10A
0.3
0.7
User Manual
EC44/E45
EC55
20A*
30A*
10A
16A
1
1.7