Tool Tab Screens
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the
Run screen. See section 2.8.1.7 Setup: Exit for further information.

2.8.5.2 Controller

Controller Tab Screens
34
Options Screen
either the PM Counter or the Trip Counter.

2.8.5.1.3 CAL Tab

Nominal Cal – This is a calculated value
based on the torque output of the motor, the
gear ratios and efficiencies. This is a
reference value only and cannot be modified.
Torque Cal – This is the specific torque
calibration value for the tool. Enter a new
value after performing a lab certification. The
Torque Cal should not deviate from the
Nominal Cal value by more than 20%.
Press EXIT when finished modifying the
value.
Options Screen
2.8.5.3
Controller
User Manual