Users Tab - Stanley Theta Controller User Manual

Table of Contents

Advertisement

Other Screens
Count Mode – Choose Count Up to indicate the fasteners that have been completed OK.
Choose Count Down to indicate the number of fasteners yet to be completed.
Stop/Abort within Limits – Choose OK to mark the fastening cycle as OK, even if the fastening
cycle is stopped or aborted while the achieved torque and angle are within limits. Choose NOK
to mark the fastening cycle as NOK (when the fastening cycle is stopped or aborted and the
achieved torque and angle values are within limits). When event occurs, this option illuminates
the red and yellow LEDs on the tool and controller.
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the
Run screen. See section 2.8.1.7 Setup: Exit for further information.
A maximum of eight users with unique passwords can be added. Passwords can contain any
character, symbol or number combination (maximum length of 16).
If users are assigned, one must be an Administrator.
If the lock icon appears, the controller is password protected. The controller automatically re-
locks the system 15 minutes after the last keypad input.
Adding users is a three step process, first choose option 1. Add:
Name user and press OK.
Second, select the new user.
Press the MANAGE interactive menu button and select option 3. Change Password.
If this is the first time adding a password, leave the Old password blank. Otherwise, key
the old password, arrow down and create a New password. Verify the password by typing
it a second time. Press OK.
Third, adjust the new user's access level by pressing the MANAGE interactive menu
button and selecting option 4. Change Access.
26
Options Screen
2.8.3.2

Users Tab

To add a user, press the MANAGE interactive
menu button.
User Manual

Advertisement

Table of Contents
loading

Table of Contents