Programming
Options Screen

2.8.3.3.2 Input Bus

The 24 VDC connector has pins 3 through 6
designated as Inputs to the controller. The pin
assignments are selectable on this tab. Use the
up/down arrows to select the pin you wish to
assign, then press the Toggle button or the
EDIT interactive menu button. A list of
available Input elements displays. See section
4.2 Assignable Input/Output Functions for the
complete list and descriptions.
Highlight the element to assign to the selected
pin and press the NEXT interactive menu
button.
An Input element can be assigned to more
than one pin. See section 4.2 Assignable
Input/Output Functions for configuration
options and descriptions.
Configure the selected input element. After
modifying press the FINISH interactive menu
button.
2.8.3.4

Triggers Tab

Tap Action – Defines the operation when the
MFB on the tool is tapped (pressed quickly).
Hold Action – Defines the operation when the
MFB on the tool is held for one second.
See section 3.4.2 MFB Mode for an
explanation of the selectable items.
Start Input – Defines inputs required to start
the tool. In all cases, the 24 VDC Start input
is always available to start the tool.