Panel Gasket (6Accgs01.Xxxx-000) - ABB B&R FT50 User Manual

Power panel
Table of Contents

Advertisement

Installation

5.4.7 Panel gasket (6ACCGS01.xxxx-000)

Caution!
In order to ensure IP67 or type 1, 12 or 4X protection, the installation instructions and corresponding
notes must be strictly followed.
It is important to note that IP67 protection is only ensured if the terminal is installed on a flat surface
of an IP67 housing. Type 1, 12 or 4X protection is also only ensured if the terminal is installed on a flat
surface of a housing with a corresponding degree of protection.
1. Apply the gasket with the flat side to the panel.
2. Guide the panel through the M22 hole.
3. Tighten the M22 nut (Torque: 10 Nm).
4. Secure the panel with at least two screws (Torque: 1.3 Nm).
48
Power Panel FT50 User's manual V1.19

Advertisement

Table of Contents
loading

Table of Contents