Installation
5.4.3 Installing an adapter bracket
Caution!
In order to ensure IP67 or type 1, 12 or 4X protection, the installation instructions and corresponding
notes must be strictly followed.
Notice!
It is important to note that when using 5CASD3.xxx0-00 SDL3/SDL4/PoE cables, the connectors pro-
trude beyond the pipe fixture.
5.4.3.1 Flange adapter (6ACCMA10.0000-000)
Information:
This accessory is compatible with the following FT50 sizes:
• 5" panel
• 7" panel
• 10.1" panel
Dimensions
Instructions
1. Attach the round panel gasket to the panel (see
2. Mount the adapter bracket.
3. Attach the second, narrower sealing ring to the adapter bracket (see
4. Tighten the M22 nut (Torque: 10 Nm).
5. Secure the flange using the two screws (Torque: 1.3 Nm).
6. Connect the cable to the panel and secure it before the panel (including the preinstalled flange adapter) is
screwed in place.