5.4.2 Installing a bracket for pipe fixtures

Caution!
In order to ensure IP67 or type 1, 12 or 4X protection, the installation instructions and corresponding
notes must be strictly followed.
Notice!
It is important to note that when using 5CASD3.xxx0-00 SDL3/SDL4/PoE cables, the connectors pro-
trude beyond the pipe fixture.
5.4.2.1 Flange feed-through (6ACCFL01.0300-000)
Information:
This accessory is compatible with the following FT50 sizes:
• 5" panel
• 7" panel
• 10.1" panel
Dimensions
Instructions
Installation of bracket for pipe fixtures as well as securing a panel is performed as follows:
1. Insert the sealing rings into the flange feed-through:
2. Attach the round panel gasket to the panel (see
3. Mount the flange feed-through including the sealing rings.
4. Tighten the M22 nut (Torque: 10 Nm).
Power Panel FT50 User's manual V1.19
37
"General information" on page
40
48.5
60
34).