Configuration
Server
Default setting: EMPTY (no server entered or selected)
In order to use the Power Panel as a VNC client, a hostname or IP address for the VNC server must be specified.
It is possible here to enter multiple servers in a list. Entering the hostname or IP address and then clicking on the
[+] icon adds the specified server in the list at the end of this services page (see "vncserver1" and "vncserver2"
in the previous image).
To use a specific VNC server from this list, it must be selected in the server list (via touch screen or mouse click).
The currently selected VNC server is displayed in input field Server.
By default, port 5900 is used to establish a connection.
If the VNC-based HMI application is available on a different port, the port number must be specified explicitly
together with the IP address or hostname:
Syntax
Example
IP address:Port
10.23.19.48:5907
Hostname:Port
vncserver1:5908
Information:
If the entered IP address is incomplete or no VNC server exists for the IP address or entered hostname,
a corresponding message will be output if a connection attempt fails in VNC mode.
This error message is only output if option Show boot logo is disabled in start mode VNC.
Password
Default setting: EMPTY (no password entered)
Input range: Max. 100 characters
Note: Only one password can be entered, which is only used for the currently selected VNC server.
If a password has been entered, then the VNC client (Power Panel) is connected to the VNC server without an
additional password query.
If no password has been entered, then the password will be queried on the Power Panel each time a connection
to the VNC server is established.
The password is stored on the device in configuration file PFT50Config.xml .
Show password
Default setting: Disabled
Enabled
The password is displayed in the input field as plain text.
Disabled
The password is hidden in the input field by placeholder characters (●●●●●●).
Encrypt password
Default setting: Disabled
Enabled
The password is stored on the device in encrypted form.
Disabled
The password is stored on the device as plain text.
Use RFB extension
Default setting: Enabled
With the RFB extension enabled, a B&R VNC server (VNC-based HMI application) can query data from the VNC
client and execute a variety of functions.
See:
"RFB extension" on page 86
66
Description
A VNC connection to IP address 10.23.19.48 is established on port 5907.
A VNC connection to host vncserver1 is established on port 5908.