7.1.1.10 Service page Update
Various parts of the system can be updated from a range of different sources on this service page.
Startup
Network
Time
Screen
Audio
Gesture
VNC
Web
Storage
Update
Backup & Reset
Security
Update settings / boot logo / system
The Power Panel system is restarted as a minimized version of the system. When restarting, the following sources
are searched in the specified order in order to find update files:
1) The USB storage medium connected to the Power Panel
For the update process, only 1 USB flash drive is permitted to be connected to the Power Panel.
2) On the configured update server (see
The following update files are searched for:
File type
Filename
PPT image
PFT50Image.img.gz, PFT50Image.info, PFT50Image.img.gz.sig (see
System settings
PFT50Config.xml (see
Boot logo
PPTLogo.bmp.gz (see
If valid update files are found during this search, they are loaded on the Power Panel and the system is restarted.
With this function, it is also possible to carry out a partial update if only a portion of the above-mentioned update
files are on the USB flash drive.
Information:
If the current settings of the Power Panel should be retained, XML file PFT50Config.xml is not permitted
to exist on the source medium.
Information:
It is generally only possible to install signed images on the Power Panel. If it is necessary to install an
unsigned image, this must be explicitly allowed beforehand on service page Security.
Load settings from USB
If no USB storage medium is connected, an appropriate message is displayed.
If a USB storage medium is connected, then a dialog box with USB interface IF3 and the name of the USB storage
medium is displayed. After selection, the settings are loaded from XML file PFT50Config.xml .
They can be checked and modified on the service pages if necessary after loading and before saving the settings.
Data is stored using functions on service page Save & Exit (see
72
Update settings / boot logo / system
Press to update settings, boot logo, system
Load settings from USB
Press to load settings from a USB flash drive
Load configuration from PLC
Press to load configuration from a PLC
Load boot logo / animation
Press to load boot logo / animation from a USB flash drive
Update server type
Specify the update server type
Get update server from DHCP server
(button)
"Configuring the update server" on page
"System settings" on page
"Boot logo" on page
(button)
"PPT image" on page
84)
85)
"Service page Save & Exit" on page
Power Panel FT50 User's manual V1.19
TFTP
74)
84)
79).