ABB B&R FT50 User Manual page 126

Power panel
Table of Contents

Advertisement

Accessories
Model number
General information
Certifications
CE
UL
HazLoc
EAC
Cable construction
Wire cross section
Properties
Outer jacket
Material
Color
Labeling
Lines
Wire insulation
Wire colors
Shield
Type
Connector
Type
Mating cycles
Contacts
Electrical properties
2)
Operating voltage
Conductor resistance
Wave impedance
Transfer properties
Insulation resistance
Operating conditions
Pollution degree per EN 61131-2
Flame-retardant
Oil and hydrolysis resistance
Degree of protection per EN 60529
Cables
RJ45 connector
Ambient conditions
Temperature
Storage
Fixed installation
Flexible installation
Mechanical properties
Dimensions
Length
Diameter
Bend radius
Fixed installation
Flexible installation
Weight
Tension
In operation
During installation
Table 20: 5CASD3.0030-00, 5CASD3.0050-00, 5CASD3.0100-00, 5CASD3.0150-00,
5CASD3.0200-00, 5CASD3.0300-00, 5CASD3.0500-00, 5CASD3.1000-00 - Technical data
1)
Yes, but applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
At 20°C ambient temperature.
126
5CASD3.
5CASD3.
5CASD3.
0030-00
0050-00
0100-00
4x 2x 26/7 AWG
HARTING INDUSTRIAL CABLE S/FTP CAT 6A PUR 4x2xAWG26/7
Green/White-green, orange/white-orange, blue/white-blue, brown/white-brown
Aluminum foil and braided wire shield composed of tinned copper wires
Bare copper strand, 4x 2x 26/7 AWG
≤100 V
≤290 Ω/km
Category 6A / Class EA up to 500 MHz per ISO/IEC
11801 (EN 50173-1), ISO/IEC 24702 (EN 50173-3)
≥500 MΩ/km
-40 to 70°C
3 m
5 m
10 m
6.7 mm
≥5x diameter
≥10x diameter
250 g
500 g
≤70 N
≤70 N
5CASD3.
5CASD3.
0150-00
0200-00
Yes
cULus E115267
Industrial control equipment
cULus HazLoc E180196
Industrial control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T4
Yes
Flame-retardant, halogen-free, lead-free
Polyurethane (PUR)
Yellow, RAL 1021
Polyethylene (PE)
2x RJ45, male
Min. 750
8
100 ±5 Ω (at 100 MHz)
Pollution degree 2
IEC 60332-1-2
EN 60811-2-1 (90°C / 7x24 h)
IP20
IP20, only when properly connected
-40 to 70°C
-40 to 70°C
15 m
20 m
700 g
950 g
Power Panel FT50 User's manual V1.19
5CASD3.
5CASD3.
5CASD3.
0300-00
0500-00
1000-00
1)
4x 2x 23/1 AWG
HARTING INDUSTRIAL INSTALLATION
CABLE S/FTP CAT 7 PUR 4x2xAWG23/1
Bare copper strand, 4x 2x 23/1 AWG
≤125 V
≤75 Ω/km
Category 7 / Class F up to 600 MHz
per ISO/IEC 11801 (EN 50173-1),
ISO/IEC 24702 (EN 50173-3)
≥5 GΩ/km
-10 to 50°C
30 m
50 m
100 m
8.3 mm
≥4x diameter
≥8x diameter
2150 g
3500 g
6950 g
≤110 N
≤110 N

Advertisement