Mount the thrust bearing.
INFORMATION
If the spindle head carrier is not exactly plugged in to "Zero" it is almost not possible to
fix the thrust bearing. Therefore if required release the clamping screws by slightly
turning the spindle head carrier before plug-in the thrust bearing.
Retighten the clamping screws after plugging them in.
4.15

Cooling

WARNING!
Discharge and overflow of cooling lubricants and lubricants Ensure that cooling
lubricants are not discharged onto the floor. Any cooling lubricants that run onto the
floor must be removed immediately.
The coolant delivery is switched on and off via a push button on the control panel.
The amount of cooling lubricant can be regulated using the dosing tap.
The friction generated during rotation can cause the edge of the tool to become very hot.
When milling it is necessary to cool down the tool depending on the material. By cooling with an
appropriate coolant lubricant you will achieve a better working result and longer durability of the
tool.
Adjust the rate of flow by means of the stop and dosing valve.
ATTENTION!
Failure of the pumps in case of dry running. The pump is lubricated by the cooling
lubricant. Do not start up the pump without cooling lubricant.
INFORMATION
Use a water-soluble environmentally friendly emulsion as cooling lubricant procured from a spe-
cialist retailer.
Respect the environment when disposing of any lubricants and cooling agents.
Follow the manufacturer's disposal instructions.