5.1.1 Explanation Of The Parameters - Optimum OPTImill MT 60 Operating Manual

Table of Contents

Advertisement

5.1.1 Explanation of the Parameters

Meanings of parameters and settings.
Parameters
Axis
P -- 07
X axis
P --– 08
Z
/Y axis
0
P --– 09
Y axis
P --– 10
X axis
P --– 11
Z
/Y axis
0
P --– 12
Y axis
P --– 13
X axis
P --– 14
Z
/Y axis
0
P --– 15
Y axis
P --– 16
X axis
P --– 17
Z
/Y axis
0
P --– 18
Y axis
P --– 19
Rotation
Speed Signal
P --– 20
EN
DPA21
40
Description
Accuracy of representations on the display:
When a higher representational accuracy value than the actual counting
resolution is set on the display, the representational accuracy value will
be shown accordingly.
Counting direction:
The counting direction of the measurement in the positive or negative
direction.
0 for a positive counting direction, 1 for a negative counting direction.
Counting resolution of the respective axis The unit is 0.1 mm.
Relation:
5µm = 50
2µm = 20
10µm = 100
The counting resolution set must correspond to the selected measuring
gib or active measuring strip reading device.
When a higher representational accuracy value than the actual counting
resolution is set on the display, the representational accuracy value will
be shown accordingly.
Correction factor:
Linear error compensation coefficient. The value range for linear error
compensation coefficients extends from -9.999 to 9.999mm, and gives
the value to be adjusted per meter.
The target value of the number of pulses per revolution of the rotation
speed signal The number of impulses per revolution of the rotation
speed signal depends on the number of output pulses per revolution of
the transducer in use (number of permanent magnets). The greater this
value is, the higher will be the resolution of the rotation speed. The
range of possible setting values extends from 1 to 3600.
Measurement time:
The target value of the time for speed measurement.
The maximum set value is 10 (i.e. 1 second) and the minimum set value
is 1 (i.e. 0.1 second).
The greater this value is, the higher will be the resolution of the revolu-
tion speed, and the slower this value will be refreshed.
The representational accuracy of the rotational speed indicator shown
directly on the display =
600 / (number of impulses per revolution x measurement time)
Translation of original instruction
Operation
Version 1.0.4 - 2020-08-04

Advertisement

Table of Contents
loading

This manual is also suitable for:

3336090

Table of Contents