The following example shows how to activate a device in slot 0 of
enclosure management device 0 using the enclosure activate slot
command:
AAC0>enclosure activate slot 0 0
Executing: enclosure activate slot 0 0
You may want to use the enclosure show slot command
again to see the change in the device slot's status, as in the
following example. Note that the OK ACTIVATE in the status
column indicates that the device is activated and working properly.
AAC0>enclosure show slot 0
Executing: enclosure show slot 0
Enclosure Slot scsiId Insert
--------- ---- ------ ------- ----------------------------------------
0
0
0:00:0
0
1
0:01:0
0
2
0:10:0
0
3
0:03:0
0
4
0:04:0
1
0
1:00:0
1
1
1:01:0
1
2
1:10:0
1
3
1:03:0
1
4
1:04:0
Related Commands
enclosure commands:
I
enclosure identify slot
I
enclosure list
I
enclosure prepare slot
I
enclosure show slot
Status
4
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE
0
OK CONFIG
0
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE
0
OK UNCONFIG ACTIVATE