The general status of an enclosure management device is
encapsulated in the following columns:
I
Enclosure
I
UpTime D:H:M
I
PowerCycle
I
Interval
I
Door
I
Alarm
The following sections describe the information that the
enclosure show status command can display in these
columns. For information about the status displays for fans, power
supplies, device slots, and temperature sensors see the
Commands
section.
The Enclosure Column
The Enclosure column displays the ID associated with the
enclosure management device that you specified on the command
line. If you did not specify an ID, the enclosure show status
command displays the IDs for all enclosure management devices
connected to the controller.
The UpTime D:H:M Column
The UpTime D:H:M column displays the total time
(days:hours:minutes) that the enclosure management device has
been running. This count is cumulative over the life of the
enclosure management device.
The PowerCycle Column
The PowerCycle column displays the number of times a user has
powered on the enclosure management device. In the example, a
user powered on enclosure management device 0 two times and
enclosure management device 1 three times. This count is
cumulative over the life of the enclosure management device.
enclosure Commands