Table of Contents

Advertisement

Configuration
6.1.6 Service page Audio
On this service page, an audio signal can be configured to be output when a touch operation occurs or controlled
by an application.
Startup
Network
Time
Screen
Audio
Hand button
Buzzer
Default setting: Enabled
Information:
The Buzzer is not supported with older hardware revisions of the Power Panel. In this case, this option
is disabled by default and cannot be enabled.
If this option is disabled, an audio signal is not output when a touch operation occurs on the Power Panel.
The following settings can be made when Buzzer is enabled:
Startup
Network
Time
Screen
Audio
Gesture
VNC
Web
Storage
Update
Buzzer source
Default setting: Touch
The following options are available for triggering a buzzer:
Touch
In
dently of the application controlled by the Power Panel operating system.
App
The RFB extension and corresponding library can be used to allow the application to trigger the audio
signal.
See:
Buzzer frequency
Default setting: 500
Input range: 40 to 15000
Unit: Hz
This setting is used to configure the frequency of the generated audio signal.
Buzzer duration
Default setting: 25
Input range: 10 to 500
Unit: ms (milliseconds)
This setting is used to configure the duration of the generated audio signal.
48
Buzzer
Buzzer
Buzzer source
Buzzer frequency
40 to 15000 Hz
Buzzer duration
10 to 500 ms
Test buzzer
Press to test
VNC and web
mode, an audio signal is output for each touch operation. This takes place indepen-
"Outputting an audio signal" on page 76
Touch
500
25
Power Panel T80 User's manual V1.03

Advertisement

Table of Contents
loading