B&R Power Panel T80 User Manual page 96

Table of Contents

Advertisement

Software
7.5.2.2.3
BuzzerWithPara
Plays the buzzer with the specified parameters. See arguments for the method call.
Information:
The Buzzer is not supported with older hardware revisions of the Power Panel. This method has no
effect in this case.
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:MethodSet/4:BuzzerWithPara
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:BuzzerWithPara
Arguments for method call
Argument
Data type
Name
0
UInt32
Frequency
1
UInt32
Duration
7.5.2.2.4
LoadConfiguration
The Power Panel loads the last saved settings and restarts. Any changes made to the
and are lost.
Function identical to:
Service page Save & Exit
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:MethodSet/4:LoadConfiguration
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:LoadConfiguration
Arguments for method call
Arguments
-
7.5.2.2.5
SaveConfiguration
Saves changes made to the parameters. Method
on the Power Panel.
Function identical to:
Service page Save & Exit
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:MethodSet/4:SaveConfiguration
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:SaveConfiguration
Arguments for method call
Arguments
-
96
Description
Frequency of the buzzer in hertz [Hz].
Duration of the buzzer in milliseconds [ms].
Exit without saving (button)
LoadConfiguration
Save changes (button)
parameters
must be used to enable these stored settings
Power Panel T80 User's manual V1.03
are not saved

Advertisement

Table of Contents
loading