Software
7.5.2.2.9
StartUpdate
Reboots the Power Panel and starts the update process.
Function identical to:
Service page Update
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:MethodSet/4:StartUpdate
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:StartUpdate
Arguments for method call
Arguments
-
7.5.2.3
Control/ConnectionWatchdog
Path to the object directory:
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:ConnectionWatchdog
ns BrowseName of the method
4
ConnectionWatchdogTimeout
ConnectionWatchdogTrigger
7.5.2.3.1 ConnectionWatchdog - Function description
If ConnectionWatchdog is active, the OPC UA client must send a trigger signal to the Power Panel within the
timeout period. If the Power Panel does not receive a trigger signal within the defined timeout period, all LEDs of
the Power Panel are disabled.
7.5.2.3.2
ConnectionWatchdogTimeout
This parameter defines the period for the watchdog timeout or disables the watchdog function.
The following values are valid for ConnectionWatchdogTimeout:
Value [ms]
Description
0
This value immediately disables the watchdog.
500 to 10000
Timeout period in milliseconds.
The client must set parameter
Path to the node (BrowsePath)
Path:
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/2:ParameterSet/4:ConnectionWatchdogTimeout
Alternative path (function group):
0:Root/0:Objects/2:DeviceSet/4:PowerPanelT80/3:Control/4:ConnectionWatchdog/4:ConnectionWatchdogTimeout
Node attributes
NodeClass
Variable
DataType
UInt16
AccessLevel
CurrentRead, CurrentWrite
UserAccessLevel
CurrentRead, CurrentWrite
98
Update settings / boot logo / system (button)
Description
This parameter defines the period for the watchdog timeout or disables the watchdog function.
This parameter is used firstly to enable the watchdog and secondly to trigger it.
OPC UA
client
Trigger
ConnectionWatchdogTrigger
Power Panel
OPC UA
server
Watchdog
timeout
to value "true" within the time defined here if the watchdog is active.
Power Panel T80 User's manual V1.03