Technical Data - B&R Power Panel T80 User Manual

Table of Contents

Advertisement

4.4 Technical data

General technical data
Model number
General information
Cooling
LEDs
System requirements
Automation Studio
Automation Runtime
Power button
Reset button
Buzzer
Support
mapp View
Controller
Operating system
Real-time clock
Processor
Type
Clock frequency
L1 cache
Data code
Program code
L2 cache
Flash
Mode/Node switches
DRAM
Interfaces
Interface IF3
Type
Variant
Current-carrying capacity
Interface IF4
Type
Variant
Current-carrying capacity
Electrical properties
Nominal voltage
Fuse
Voltage range
Reverse polarity protection
Operating conditions
Installation elevation above sea level
0 to 2000 m
>2000 m
Degree of protection per EN 60529
Mechanical properties
Front
Design
1)
The internal fuse cannot be replaced by the user or reset.
Model number
Electrical properties
Power consumption
1)
Operating conditions
Permissible mounting orientations
Standard mounting orientation
Tilt
Rotation
Ambient conditions
Temperature
Operation
Derating
Storage
Transport
Relative humidity
Power Panel T80 User's manual V1.03
6PPT80.0702-xxx
Max. 13.5 W
2)
In 90° increments (portrait/landscape)
6PPT80.xxxx-xxx
Passive
Ethernet (Link, Activity, Speed)
4.7.1 or higher
4.71 or higher
No
No
Yes
Recommended widget classes: A, B, C
PPT80 system
No
Atom E3930
2x 1.3 GHz
24 kB
32 kB
1 MB for 2 CPU cores
512 MB
No
1 GB LP DDR4 RAM
USB 2.0
Type A
0.5 A
USB 2.0
Type A
0.5 A
24 VDC
3 A slow-blow, internal
24 VDC (-15% / +20%)
Yes
No limitation
Reduction of ambient temperature by 0.5°C per 100 m
Front: IP55, Back: IP20
Black
6PPT80.101E-xxx
6PPT80.121E-xxx
Max. 16 W
Vertical
±25°
-20 to 60°C
See section "Derating".
-20 to 80°C
-20 to 80°C
See temperature/humidity diagram.
Device description
1)
6PPT80.156B-xxx
Max. 17 W
Max. 23.5 W
-20 to 70°C
-20 to 70°C
-
17

Advertisement

Table of Contents
loading

Table of Contents