Connect M12 Cable Socket To The Cable - Siemens SITRANS P Operating Instructions Manual

Pressure transmitter
Hide thumbs Also See for SITRANS P:
Table of Contents

Advertisement

Connecting

6.4 Connect M12 cable socket to the cable

Requirement
● The terminal area of the cable socket is suitable for cables with diameters ranging from 6 to
12 mm.
● These cables use stranded wires with 1 mm
● You are using a crimping tool from HARTING (article number 09 99 000 0110).
Procedure
1. Slide the sleeve and the screwed joint on the cable.
2. Strip approx. 8 mm of the cable ends.
3. Crimp the contact parts on the cable ends.
4. Assemble the cable socket.
Connector pin assignment with Han 7D or
Han 8D plug or cable socket
6.4
Connect M12 cable socket to the cable
Loss of safety required for approval by using the M12 device plug.
You may only use the plug for non-Ex devices; otherwise, the safety required for the approval
is not guaranteed.
Note
A conductive connection must not exist between the shield and the connector housing.
Note
Observe the protection class of the M12 device plug when defining the protection class.
In devices where a plug is already mounted on the enclosure, the connection is made via a
cable socket.
1. Thread the parts of the cable socket as described by the manufacturer of the cable socket.
2. Strip approximately 18 mm of the bus cable
72
WARNING
as single conductors ("+", "-" and ground).
2
I
Output current
A
U
Auxiliary power
H
.
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC