Absolute Pressure From The Differential Pressure Series - Siemens SITRANS P Operating Instructions Manual

Pressure transmitter
Hide thumbs Also See for SITRANS P:
Table of Contents

Advertisement

Technical data
13.1 Input
The MAWP value of the pressure transmitter can be lower than the PN value of the mounting
2)
flange and vice versa. To determine the maximum permissible operating pressure and the
maximum permissible test pressure, use the lowest value as reference.
Absolute pressure measuring limits with front-flush diaphragm
Lower measuring limit
● Measuring cell with silicone oil filling
Upper measuring limit
Lower range value
13.1.6

Absolute pressure from the differential pressure series

Absolute pressure input from the differential pressure series
Measured variable
Measuring span (continuous‐
ly adjustable) and maximum
operating pressure (accord‐
ing to 2014/68/EU Pressure
Equipment Directive)
For devices with functional safety, the minimum permissible measuring span is limited by the
1)
spread. Therefore, ensure that the configured spread is no higher than 5:1.
Absolute pressure measuring limits from dif‐
ferential pressure series
Lower measuring limit
● Measuring cell with silicone oil filling
● Measuring cell with inert liquid
For process temperature -20 °C <
ϑ ≤ 60 °C (-4 °F < ϑ ≤ +140 °F)
204
Absolute pressure
Measuring span
1)
8.3 ... 250 mbar a
0.83 ... 25 kPa a
3 ... 100 inH
O a
2
43 ... 1300 mbar a
4.3 ... 130 kPa a
17 ... 525 inH
O a
2
166 ... 5000 mbar a
16.6 ... 500 kPa a
2.41 ... 72.5 psi a
1 ... 30 bar a
0.1 ... 3 MPa a
14.5 ... 435 psi a
5 ... 100 bar a
0.5 ... 10 MPa a
76.9 ... 1450 psi a
0 mbar a/kPa a/psi a
30 mbar a/3 kPa a/0.44 psi a
0 mbar a/kPa a/psi a
100% of max. range
Between the measuring limits (continuously adjustable)
Maximum permissible
operating pressure
MAWP (PS)
160 bar a
16 MPa a
2320 psi a
160 bar a
16 MPa a
2320 psi a
160 bar a
16 MPa a
2320 psi a
160 bar a
16 MPa a
2320 psi a
160 bar a
16 MPa a
2320 psi a
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC
Max. permissible
test pressure
240 bar a
24 MPa a
3480 psi a
240 bar a
24 MPa a
3480 psi a
240 bar a
24 MPa a
3480 psi a
240 bar a
24 MPa a
3480 psi a
240 bar a
24 MPa a
3480 psi a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans p320Sitrans p420

Table of Contents