Functional Principle - Siemens SITRANS P Operating Instructions Manual

Pressure transmitter
Hide thumbs Also See for SITRANS P:
Table of Contents

Advertisement

Description

4.4 Functional principle

Nameplate with information on the remote seals
The nameplate with information on the remote seals is located on the back of the enclosure.
Figure 4-6
4.4
Functional principle
This chapter describes how the pressure transmitter works.
First the electronics are described, and then the physical principle of the sensors which are
used with the various device versions for the individual measurement types.
30
Diaphragm remote seals of sandwich type
Article number (MLFB number)
Order supplement (order code)
Serial number
Operating temperature
Vacuum service: No, oxygen ≤ 60 °C;
≤ 50 bar
Example
Nominal diameter/nominal pressure: 4 inch, 50
mm tube length, CLASS 600
Filling liquid: Food grade oil (FDA-compliant)
Wetted materials: Diaphragm duplex, 1.4462
QR code for mobile website with device-specific
information
Assembly and manufacturing location
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans p320Sitrans p420

Table of Contents