11.3.3.3

Replacing the termination board

Removing the termination board
1. De-energize the device.
2. Use a 3 mm Allen key to loosen the front safety catch
3. Open the cover of the electronic connection compartment.
4. Disconnect the cables from the termination board.
5. On the left and right side, remove the recessed-head screws
board to the enclosure.
6. Remove the termination board.
Installing the termination board
1. Insert the new termination board so that its contact pins
board.
2. Work in the reverse order to that described in "Removing the termination board".
SITRANS P320/P420 with 4 to 20 mA/HART
Operating Instructions, 11/2019, A5E44852162-AC
Service and maintenance
11.3 Maintenance and repair work
.
that hold the termination
fit on the rear of the termination