B.
Use the jam nut to compress any spring
that measures greater than 3.96 cm (1.56
inches).
1. Boom-hinge spring
4.
Repeat the procedure for each spring on both
boom hinges.
5.
Move the boom sections into the transport "X"
position; refer to
Cradle (page
31).
2
Assembling the Sprayer
Tank Fill Fitting
Parts needed for this procedure:
1
Quick-disconnect fitting
Procedure
Note:
To complete this procedure, you will need to
supply a hose with 1 inch male national pipe thread
(NPT) fitting and PTFE thread sealant.
1.
At the forward, right side of the tank cover,
remove the 2 hairpins that secure the latches for
the quick-disconnect coupling for the anti-siphon
fill receptacle
(Figure
Figure 3
2. Jam nut
Operating the Boom-Transport
4).
1. Quick-disconnect fitting
g002332
2. Hairpins
2.
Rotate the latches open to unlock
the quick-disconnect fitting from the
quick-disconnect coupling
3.
Remove the quick-disconnect fitting from the
quick-disconnect coupling
4.
Close the latches and install the hair pins into
the flanges of the quick-disconnect coupling
(Figure
4).
5.
Apply PTFE thread sealant
threads of the fill hose fitting (1 inch—national
pipe thread).
1. PTFE thread sealant
2. Fill-hose fitting (1
inch—national pipe
thread)
6.
Thread the quick-disconnect coupling onto the
fill hose and tighten it by hand
16
Figure 4
3. Latches (quick-disconnect
coupling)
(Figure
4).
(Figure
4).
(Figure
5) to the
Figure 5
3. Quick-disconnect fitting
(Figure
5).
g191617
g191615