Toro Multi Pro 5800-G Operator's Manual page 35

Turf sprayer with excelarate spray system
Hide thumbs Also See for Multi Pro 5800-G:
Table of Contents

Advertisement

Figure 34
5.
Shut off the master section switch, set the
throttle to the slow position, shut off the spray
pump, and shut off the engine.
6.
Set the graduated container on a level surface
and note the fluid volume
Important:
When you are reading the
graduated container, you must set the
container on a level surface.
Important:
When you are reading the
graduated container, read the fluid volume in
the graduated container at the lowest point
of the fluid-surface curve.
Important:
Small errors reading the fluid
volume in the graduated container will
significantly impact the accuracy of the
sprayer calibration.
Figure 35
1. Highest point of the
fluid-surface curve (do not
measure here)
2. Lowest point of the
fluid-surface curve
(measure here)
g193177
(Figure
35).
g193829
3. Level surface
7.
Compare the volume of water in the graduated
container with the nozzle volume in the
15-second catch test table.
15-Second Catch Test Table
Nozzle Color
Milliliters
collected in 15
seconds
Yellow
189
Red
378
Brown
473
Gray
567
White
757
Blue
946
Green
1,419
8.
If the fluid level in the graduated catch container
is 7.4 ml (1/4 fl oz) more or less than the nozzle
volume in the 15-second catch test table,
perform 1 of the following:
Perform a flow calibration, or replace worn
nozzles and perform a flow calibration;
refer to the flow calibration procedure in the
Software Guide for the Multi Pro 5800-D and
5800-G turf sprayer with ExcelaRate spray
system.
Calibrate the agitation bypass valve, or
replace worn nozzles and calibrate the
agitation bypass valve; refer to
the Agitation-Bypass Valve (page
35
Ounces collected
in 15 seconds
6.4
12.8
16.0
19.2
25.6
32.0
48.0
Calibrating
39).