Toro Multi Pro 5800-G Operator's Manual page 34

Turf sprayer with excelarate spray system
Hide thumbs Also See for Multi Pro 5800-G:
Table of Contents

Advertisement

7.
Set the individual section switches, as needed,
to the O
position; refer to
N
in the Application Rate Mode (page
8.
Use the application-rate switch to achieve the
desired spray pressure as indicated in the
nozzle-selection guide provided with the sprayer
(Figure
32).
1. Application-rate switch
9.
Drive at the desired speed and then set the
master section switch to the O
spraying; refer to
Application Rate Mode (page
Note:
When the tank is nearly empty, the
agitation may cause foaming in the tank. In
this case, turn the agitation switch to the O
position. Alternatively, you can add anti-foaming
agent to the tank.
10.
When you are finished spraying, set the master
section switch to the O
sections, then set the spray-pump switch to the
O
position.
FF
Note:
Return the sections to the transport
position and drive the sprayer to the cleaning
area.
Important:
Always raise the sections
until they have moved completely into
section-transport cradle forming the "X"
transport position and the section cylinders
are fully retracted whenever you move the
sprayer from 1 spraying area to another, or
move to a storage or cleaning area.
Catch Test
Customer provided equipment: A graduated
catch container (a container with 0.01 ml (1/2 fl. oz)
increments is preferred) and stop watch.
Figure 29
in
32).
Figure 32
position to begin
N
Figure 29
in
Spraying in the
32).
position to turn off all
FF
Preparing for the Catch Test
Spraying
1.
Ensure that the sprayer tank is clean; refer to
Cleaning the Sprayer System (page
2.
Fill the sprayer tank with at least 568 L (150 US
gallons) of fresh water; refer to
Tank (page
3.
Ensure that the nozzles that you intend to test
are in the active spray (down) position.
4.
For machines operated in the application-rate
mode, ensure that the knob for the
section-bypass shutoff valve is in the closed
position
g195528
1. Section-bypass shutoff valve (closed position)
FF
5.
For machines operated in the application-rate
mode, ensure that the section-bypass shutoff
valve is closed
6.
Engage the parking brake and start the engine.
Note:
7.
For machines operated in the application-rate
mode, perform the steps in Using the Test
Speed; refer to the Software Guide for the
Multi Pro 5800-D and 5800-G turf sprayers with
ExcelaRate spray system.
Note:
km/h (2 mph) and 14 km/h (9 mph).
Performing a Catch Test
1.
Set the spray section switch(es) to the O
position for the section(s) that you are testing.
2.
Set the throttle to the F
3.
Set the master section switch to the O
4.
Perform a 15-second catch test at 1 of the active
spray nozzles.
34
30).
(Figure
33).
Figure 33
(Figure
33).
Allow the engine to warm for 10 minutes.
Set the simulated test speed between 4
position.
AST
36).
Filling the Spray
g192607
N
position.
N

Advertisement

Table of Contents
loading

This manual is also suitable for:

41394

Table of Contents