Ametek Ortec radEAGLET-R Series User Manual page 155

Table of Contents

Advertisement

radEAGLET-R User Manual
... continuation
Storage, Transport
29
Temperature Change
30
Relative Humidity
31
Protection Rating
32
Explosive Atmospheres
33
Battery
Type
34
Li-Ion: Capacity
35
Li-Ion: Operating Duration
36
Li-Ion: Operating Duration
37
Li-Ion: Charging Duration
38
Li-Ion: Storage
39
NiMH: Capacity
40
NiMH: Operating Duration
41
NiMH: Operating Duration
42
NiMH: Charging Duration
43
NiMH: Storage
44
Display
Type
45
Size
46
Central Luminance
47
Annunciators
Red LED
48
© innoRIID GmbH • 2020-11-18
-20 °C — +50 °C (-4 °F — +122 °F); <2.1 bar
(30.46 psi)
Sudden temperature change must not
exceed 40.0 °C (72.0 °F) in order to avoid
damage to the detector crystal.
10 % — 80 %, non condensing
IP66 according to IEC 60529
NOT certified for use in explosive
environments
powerCELL; rechargeable; exchangeable;
Li-Ion; LSD NiMH by request
>3350 mAh; 7.2 V
≥12 h at 20 °C (68 °F) in dose rate mode
with dimmed display back light and GPS
switched off
≥7 h at -20 °C (-4 °F) in dose rate mode with
dimmed display back light and GPS switched
off
5 h at 20 °C (68 °F) when instrument off
Please recharge every 12 months
>2700 mAh; 7.2 V
≥8.5 h at 20 °C (68 °F) in dose rate mode
with dimmed display back light and GPS
switched off
≥6 h at -20 °C (-4 °F) in dose rate mode with
dimmed display back light and GPS switched
off
5 h at 20 °C (68 °F) when instrument off
Please recharge every 6 months
Transflective color TFT LCD
3.5 in (88.9 mm); 480 pixel × 640 pixel
250 cd/m² (typical)
Gamma warning and alarm reporting;
startup indication
Software 3.2.12r • Document 3.3.3b4o