3 - Description
Menu 4.6 PrimeFlow setup
This menu is to setup and test the PrimeFlow function.
It is advisable to contact the HARDI Dealer prior to attempt
changing these settings.
Menu 4.6.1 Test Nozzle positions
The nozzle position test confirm that all the nozzles are able to
open and close at the same time. It also tests that the nozzles are
programmed to be on the correct place on the boom.
This is done by first opening all the nozzles and then closing them
again. Then the nozzles, will open for 2 sec. one by one from the
left to the right side of the boom.
At this test the nozzle farthest to the left should open first and then
the nozzle next to it on the right side.
If the sequence jump from one nozzle to another nozzle, not in
consecutive order, the system has to be reprogrammed.
Menu 4.6.2 Assign nozzle position to SMCU
Assign nozzle position to SMCU when replacing a SMCU on the
boom.
The PrimeFlow system is programmed in this menu where the
SMCU is programmed with a unique ID number, a position on the
boom and a nozzle position is assigned to the SMCU.
The programming of the system has to be done before the system
is operational.
68
T o o l b o x
M e n u
S e r v i c e i n t e r v a l : H o u r s u n t i l
S e r v i c e i n t e r v a l r e s e t
T e s t M e n u
S p e e d s i m u l a t i o n
E m e r g e n c y M o d e
P r i m e F l o w s e t u p
S e t u p a n d t e s t S M C U ' s
P r i m e F l o w s e t u p
M e n u
T e s t N o z z l e p o s i t i o n s
A s s i g n n o z z l e p o s i t i o n t o S M C U
R e s e t n o z z l e p o s i t i o n i n S M C U
E a c h n o z z l e i s o p e n f o r 2 s e c .
C h e c k t h a t s e q u e n c e
d o e s n o t j u m p
P r i m e F l o w s e t u p
M e n u
T e s t N o z z l e p o s i t i o n s
A s s i g n n o z z l e p o s i t i o n t o S M C U
R e s e t n o z z l e p o s i t i o n i n S M C U
A s s i g n n o z z l e p o s i t i o n
Need help?
Do you have a question about the SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?
Questions and answers