3 - Description
Menu Number
Menu Name
2. 1. 1. 18
Extra sensor 1F
2. 1. 1. 19
Extra sensor 2F
2. 1. 1. 20
Extra sensor 3A
2. 1. 1. 21
Extra sensor 4A
2. 1. 1. 22
Voltmeter
2. 1. 1. 23
Agitation
2. 1. 1. 24
RinseTank content
2. 1. 1. 25
Slant angle
2. 1. 1. 26
Boom height
2. 1. 1. 27
Air pressure
2. 1. 1. 28
Reserved
2. 1. 1. 29
Reserved
2. 1. 1. 30
Reserved
2. 1. 1. 31
Reserved
2. 1. 1. 32
Reserved
2. 1. 1. 33
Nozzle size flow at 3 bar
2. 1. 1. 34
Reserved
2. 1. 1. 35
Hitch Angle
2. 1. 1. 36
Linkage Angle
2. 1. 1. 37
PF bus +
2. 1. 1. 38
PF bus -
2. 1. 2
Show upper right
2. 1. 2. 01
Prog volume rate litre/ha
2. 1. 2. 02
Boom flow
2. 1. 2. 03
Time
2. 1. 2. 04
Work rate ha/hour
2. 1. 2. 05
Actual volume rate litre/ha
2. 1. 2. 06
Tank contents
2. 1. 2. 07
Speed
2. 1. 2. 08
Volume sprayed
2. 1. 2. 09
Area sprayed
2. 1. 2. 10
Active boom size
2. 1. 2. 11
Pressure
2. 1. 2. 12
Fan speed
2. 1. 2. 13
Wind Speed
2. 1. 2. 14
Pendulum lock status
2. 1. 2. 15
Pendulum unlock status
2. 1. 2. 16
Dynamic centre position
2. 1. 2. 17
Spray pump rev
2. 1. 2. 18
Extra sensor 1F
2. 1. 2. 19
Extra sensor 2F
2. 1. 2. 20
Extra sensor 3A
2. 1. 2. 21
Extra sensor 4A
2. 1. 2. 22
Voltmeter
2. 1. 2. 23
Agitation
2. 1. 2. 24
RinseTank content
2. 1. 2. 25
Slant angle
2. 1. 2. 26
Boom height
2. 1. 2. 27
Air pressure
2. 1. 2. 28
Reserved
2. 1. 2. 29
Reserved
2. 1. 2. 30
Reserved
2. 1. 2. 31
Reserved
38
Help Text in Display
Readout from extra sensor 1 frequency
Readout from extra sensor 2 frequency
Readout from extra sensor 3 analogue
Readout from extra sensor 4 analogue
Displays system voltage. Useful when fault finding
Agitation valve opening
RinseTank calculated content
Headland assist angle sensor
Headland assist height sensor
Displays compressor air pressure if sensor is fitted
R R
R R
R R
R R
R R
Calculated nozzle flow at 3 bar
R R
Voltage on PrimeFlow databus +
Voltage on PrimeFlow databus -
Shows Programmed volume rate Application rate litre per hectare
Boom flow per minute sprayed out through the boom
Actual time
Rate shown in hectare per hour or acre per hour
Actual rate in litre per hectare or gallon per acre
Main tank contents
Driving speed
Readouts for Volume sprayed in currently active register
Readouts for Area sprayed in currently active register
Active boom size including end nozzle
Displays spray pressure if sensor is fitted
Displays Twin fan speed if sensor is fitted
Displays wind speed if sensor is fitted
Displays reading of pendulum lock sensor if fitted
Displays reading of pendulum unlock sensor if fitted
Displays Dynamic centre position sensor if fitted
Displays revolutions if sensor is fitted
Readout from extra sensor 1 frequency
Readout from extra sensor 2 frequency
Readout from extra sensor 3 analogue
Readout from extra sensor 4 analogue
Displays system voltage. Useful when fault finding
Agitation valve opening
RinseTank calculated content
Headland assist angle sensor
Headland assist height sensor
Displays compressor air pressure if sensor is fitted
R R
R R
R R
R R