Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Original Instruction Book page 123

Table of Contents

Advertisement

ID
Type
Fault Text at Display
(PG)
32
Illegal action No rinse water
33
Warning
Steering not active Over speed
34
Waiting
Start FlexCapacity pump
35
Waiting
Stop FlexCapacity pump
36
Waiting
Pause
37
Warning
PrimeFlow Comm. Fault
38
Warning
Output failing to sect 1
39
Warning
Output failing to sect 2
40
Warning
Output failing to sect 3
41
Warning
Output failing to sect 4
42
Warning
Output failing to sect 5
43
Warning
Output failing to sect 6
44
Warning
Output failing to sect 7
45
Warning
Output failing to sect 8
46
Warning
Output failing to sect 9
47
Warning
Output failing to sect 10
48
Warning
Output failing to sect 11
49
Warning
Output failing to sect 12
50
Warning
Output failing to sect 13
51
Warning
Output failing to bypass
52
Warning
Nozzle valve air pressure too low
56
Warning
Rinse tank not full
58
Warning
Sections OFF
83
Reminder
Aborted by Keypress
84
Warning
AutoWash exception alarm #
88
Reminder
Check filters & brakes
89
Reminder
Grease points
90
Reminder
Tighten bolts
91
Reminder
Miscellaneous service
92
Reminder
Check nozzles
94
Warning
Rollover-protection activated
95
Changed
Track is in auto
Criteria for Fault
Operations Disabled
When pressing soft key for either BoomFlush,
FastFlush, MultiRinse while RinseTank is
calculated too empty for that program.
Key press does not start process.
Used by AutoWash/AutoFill.
Valves are positioned as in AutoWash table.
After press on soft key computer continues to
next step.
See also screen layouts.
Used by AutoWash/AutoFill
Valves are positioned as in AutoWash table.
After press on soft key computer continues to
next step. See also screen layouts.
Used by AutoWash/AutoFill.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
Detected by H-bridge on I2C bus.
When MainTank has been filled and RinseTank is
empty.
7 - Fault Finding
Help Text
Not enough rinse water for selected program.
AutoWash cannot be started.
Double pump must be started to flush hoses.
Stop and start Double pump with hydraulic
lever, as Warning prompts you to.
Double pump must be stopped to avoid
chemical in boom.
Stop and start Double pump with hydraulic
lever, as Warning prompts you to.
Output failing to sect 1
Output failing to sect 2
Output failing to sect 3
Output failing to sect 4
Output failing to sect 5
Output failing to sect 6
Output failing to sect 7
Output failing to sect 8
Output failing to sect 9
Output failing to sect 10
Output failing to sect 11
Output failing to sect 12
Output failing to sect 13
Remember to re-fill rinse tank.