Menu Number
Menu Name
3
Calibration
3. 1
Speed calibration
3. 1. 1
Sprayer speed
3. 1. 1. 1
Sprayer speed constant
3. 1. 1. 2
Sprayer speed practical
3. 1. 1. 2. 1 Sprayer practical
3. 1. 1. 2. 2 Sprayer practical
3. 1. 1. 2. 3 Sprayer practical
3. 1. 2
Speed from SmartCom or IsoBus
3. 1. 2. 1
Speed Sensor or Radar
3. 1. 2. 2
Speed via ISOBUS
3. 2
Flow calibration
3. 2. 1
PPU theory method
3. 2. 2
Nozzle method
3. 2. 2. 1
Nozzle method
3. 2. 2. 2
Nozzle method
3. 2. 2. 3
Flow calibration
3. 2. 2. 4
Nozzle method
3. 2. 2. 5
Nozzle method
3. 2. 3
Tank method
3. 2. 3. 1
Tank method
3. 2. 3. 2
Tank method
3. 2. 3. 3
Flow calibration
3. 3
Boom setup
3. 3. 1
Width
3. 3. 2
Number of sections
3. 3. 3
Nozzles / sections
3. 3. 3. 01
Nozzles / sections
3. 3. 3. 02
Nozzles / sections
3. 3. 3. 03
Nozzles / sections
3. 3. 3. 04
Nozzles / sections
3. 3. 3. 05
Nozzles / sections
3. 3. 3. 06
Nozzles / sections
3. 3. 3. 07
Nozzles / sections
3. 3. 3. 08
Nozzles / sections
3. 3. 3. 09
Nozzles / sections
3. 3. 3. 10
Nozzles / sections
3. 3. 3. 11
Nozzles / sections
3. 3. 3. 12
Nozzles / sections
3. 3. 3. 13
Nozzles / sections
3. 4
Regulation user setup
3. 4. 1
Flow sensor restriction
3. 4. 2
Simulated speed value
3. 4. 3
Nozzle size flow at 3 bar
3. 4. 4
Dual line second nozzle
3. 4. 5
Type of nozzle
3. 4. 5. 1
Regular nozzle
3. 4. 5. 2
QuintaStream
3. 4. 6
ASC map headland gap
3. 4. 6. 1
HARDI/AgLeader displays
3. 4. 6. 2
3rd party ISO displays
3. 4. 7
Limit for sim speed value
3. 4. 8
Reserved
Help Text in Display
Basic calibration ,e.g. speed, boom, regulation constant, tank and track
Sprayer, tractor, Alpha or radar speed input. Calibration of selected sensor
Speed sensor mounted on trailed sprayer Connected to armature junction box
Shows and permits change to the constant, Pulses Per Unit (meter / feet)
Preferred method. Do in field with spray tank half full for most accurate result
Measure up a distance more than 70 meters or 200 feet. Then drive distance
Now key in the exact distance, measured by a measuring tape
This is the new constant (pulses per meter or feet)
Choose sensor connected to SmartCom or via CanBus
SmartCom pin input from sprayer wheel speed sensor or from tractor radar connector
Speed via ISOBUS cable from GPS or Tractor ECU
Flow sensor calibration. Theoretical (PPU), Nozzle Tank method PrimeFlow
Use the PPU value on Flowmeter housing
Practical flow calibration, by checking the actual nozzle output per minute
measure the flow per minute from a number of nozzles. Press Enter.
Key in the averaged actual flow value and press Enter
This is the PPU constant from the volume previously just measured
Open all sections
Close end nozzles, Bi-jet nozzles
Practical flow calibration done by emptying over half the tank
The sprayed amount is counted up when the sections are opened
Press Enter. The shown volume is adjusted to match the actual volume
This is the PPU constant from the volume previously just measured
Boom width, number of sections and number of nozzles for each section
The total spray boom width. Include end nozzles if fitted
The number of spray boom sections. Keyin, then press Enter
To set up no. of nozzles per section. Screens for each section will appear
Use arrow keys or numeric keys, then press Enter to set up section 1
Use arrow keys or numeric keys, then press Enter to set up section 2
Use arrow keys or numeric keys, then press Enter to set up section 3
Use arrow keys or numeric keys, then press Enter to set up section 4
Use arrow keys or numeric keys, then press Enter to set up section 5
Use arrow keys or numeric keys, then press Enter to set up section 6
Use arrow keys or numeric keys, then press Enter to set up section 7
Use arrow keys or numeric keys, then press Enter to set up section 8
Use arrow keys or numeric keys, then press Enter to set up section 9
Use arrow keys or numeric keys, then press Enter to set up section 10
Use arrow keys or numeric keys, then press Enter to set up section 11
Use arrow keys or numeric keys, then press Enter to set up section 12
Use arrow keys or numeric keys, then press Enter to set up section 13
Setup of pressure filter, nozzle, ASC default
Flow to obtain 1 bar pressure drop over pressure filter and flow sensor
Type in speed for priming at stand still and when both flow and pressure are defect
Nozzle output l/min
0075Pink = 0.3; 02Yellow = 0.8 04Red = 1.6; 08White = 3.2 l/min
Select Regular or QuintaStream nozzle
Flat fan, Low drift, Minidrift
QuintaStream fertiliser nozzle
ASC map headland gap display setup
HC 8500, HC9500, Versa, Integra, HC 8600, HC 9600, InCommand
John Deere, TopCon, ME (including HC7500), Trimble and other
Type in limit for simulated speed value
Reserved Reserved Reserved
3 - Description
41
Need help?