7 - Fault Finding
ID
Type
Fault Text at Display
(PG)
96
Changed
Track is Locked
97
Changed
Reversing
98
Reminder
AutoFill setpoint reached
99
Alarm
PrimeFlow data cable weakness
100
Alarm
Low Prime- Flow voltage
101
Warning
PrimeFlow power cable defect
102
Warning
PrimeFlow computer defect
103
Warning
Fold with unlocked pendulum
105
Changed
Agitation in auto
107
Warning
Slant angle sensor fault
108
Alarm
Boom height sensor fault
110
Warning
Tank sensor fault
112
Changed
Flat 1 Level 1 Hilly 5
113
Changed
Flat 1 Level 2 Hilly 5
114
Changed
Flat 1 Level 3 Hilly 5
115
Changed
Flat 1 Level 4 Hilly 5
116
Changed
Flat 1 Level 5 Hilly 5
117
Warning
D-centre incorrect position
118
Warning
Pendulum locking failed
119
Warning
Pendulum release failed
120
Warning
STOP! PENDULUM LOCKED!
121
Alarm
Pendulum lock sensor
122
Warning
Edit filled above content
123
Warning
Folding not allowed
124
Reminder
TODO_1
125
Reminder
TODO_3
126
Reminder
NO DILUTION
127
Reminder
TANK DILUTION
128
Reminder
BOOM DILUTION
131
Warning
Boom not in transport
132
Illegal action One function only
133
Illegal action Unfold inner wing
134
Illegal action Keep folding 1st outer wing
135
Illegal action Keep folding 2nd outer wing
124
Criteria for Fault
Operations Disabled
Warning is active when 2.2.4.3 Slant mirror is
enabled and/or if 2.2.4.4 Slant in steps is
enabled.
The warning is generated, if the sensor signal
is less than0.2 Volt or exceeds 4.8 Volt.
Appears when dilution kit function is
activated, and no outputs are active.
Appears when dilution kit function is
activated, and tank output is active.
Appears when dilution kit function is
activated, and Boom output is active.
Help Text
Check sensor and cable on pendulum.
Disable HeadlandAssist.
Disable Slant in steps.
Fluid systems works normally.
Suction from rinse tank.
Flush tank through tank cleaning nozzles.
Suction from rinse tank.
If nozzles are open - flush feed hoses.
If nozzles are closed - flush dump hose.