TROUBLESHOOTING
PDA SOFTWARE IS LOCKED UP
✓ If the PDA software is locking up, if may be due to a lack of
free memory space. This is most likely caused by other
programs running in the background. To close unnecessary
programs that may be running:
✓ Press Start and select Settings from the dropdown menu.
✓ Press the 〈System〉 button at the bottom of the display.
✓ Press the Memory icon.
✓ Press the 〈Running Programs〉 button at the bottom of
the display.
✓ Press the 〈Stop All〉 button to halt all programs currently
running in the PDA memory.
PDA devices run programs in the background, even
when these programs are "closed." Therefore, the above
procedure may need to be repeated regularly. Refer to
the PDA user manual for more information.
✓ If the PDA memory has been completely depleted, the PDA
may remain in a locked up state. In this case:
✓ Remove the PDA battery pack.
✓ Press the Reset button located beneath the battery pack.
✓ Reinstall the battery pack.
✓ The PDA will reboot several times (this may take a few
minutes).
✓ Wait until the PDA displays the Troxler menu (see Figure
3–4 on page 3–10).
✓ Turn the gauge on.
✓ Press the 〈Troxler 3451〉 button to initiate communications
between the PDA and gauge.