Wiring example of using the external power supply
・The wiring example below is for A / B phase, origin signal differential input type.
・Connect the ground of external power supply and the sensor to the EX0V, please set the same potential of the
control ground of inside the servo driver.
・Open the EX5V terminals, make sure that no voltage is supplied this terminals.
Detection head
Feedback scale unit
R2.0
+5V
0V
+5V
0V
A
A
B
B
Z
Z
FG
+5V
0V
CS-GND
CS3
CS2
CS1
FG
Scale
Industrial Device Solution Business Unit, Panasonic Corporation
External power supply
+5V 0V
X5
1
EX5V
2
EX0V
3
4
5
EXA
6
EXA
7
EXB
8
EXB
9
EXZ
10
EXZ
X6
1
E5V
2
E0V
3
4
CS3
5
CS2
6
CS1
Servo driver