Panasonic MINAS A6B Series Reference Specifications page 103

Ac servo driver for linear motor/dd motor (standard type/multi-function type)
Table of Contents

Advertisement

PARAMETER
Default
Cate
Pr.
Parameter
Cate
value
2
0 Adaptive filter mode setup
0
1 1st notch frequency
5000
2 1st notchwidth selection
2
3 1st notch depth selection
0
4 2nd notch frequency
5000
5 2nd notch width selection
2
6 2nd notch depth selection
0
7 3rd notch frequency
5000
8 3rd notch width selection
2
9 3rd notch depth selection
0
10 4th notch frequency
5000
11 4th notch width selection
2
12 4th notch depth selection
0
Selection of damping filter
13
0
switching
14
1st damping frequency
0
*1
15
1st damping filter setup
0
*1
16
2nd damping frequency
0
*1
17
2nd damping filter setup
0
*1
18
3rd damping frequency
0
*1
19
3rd damping filter setup
0
*1
20
4th damping frequency
0
*1
21
4th damping filter setup
0
*1
22
Size A-C 9.2
Command smoothing filter
*1
Size D-H 13.9
23
Command FIR filter
1.0
*1
24 5th notch frequency
5000
25 5th notch width selection
2
26 5th notch depth selection
0
27 1st damping width setting
0
28 2nd damping width setting
0
29 3rd damping width setting
0
30 4th damping width setting
0
*1 When checking directly value of parameter-file with a text data etc., it does not show the decimal point.  Ex) Pr6.24 Load change compensation filter ・・・ Value of Panaterm : 0.53 / Value of parameter-file : 53
* Parameter names in the table correspond to the DD motor (rotary type). For parameter names and setting values corresponding to linear motors, refer to the technical document.
MODEL
MINAS-A6B(BL/BM) series
Default
Pr.
Parameter
Cate
value
2
31 For Manufacturer use
0
32 For Manufacturer use
0
33 For Manufacturer use
0
34 For Manufacturer use
0
35 For Manufacturer use
0
36 For Manufacturer use
0
37 For Manufacturer use
0
Default
Pr.
Parameter
Cate
Pr.
value
Default
Parameter
Cate
Pr.
Parameter
value
No.SX-DSV03335
 3/11
Default
value

Hide quick links:

Advertisement

Table of Contents
loading