Feedback pulse of the feedback scale / Position compare output
[1] Use an RS422 line receiver (AM26C32 or equivalent) to receive output pulse.
At that time, install an appropriate terminating resistor (approx. 330 Ω) between the line receiver inputs.
[2] The maximum output frequency should be 4 Mpps (after quad edge evaluation) or less.